e3 Diagnostics

Audiologists use tympanometry measurements to test the middle ear's mobility when changes in air pressure occur. Recorded on a graph called a tympanogram, the results of tympanometry tests offer information about air pressure in the middle ear. Middle-ear tympanometry helps audiologists diagnose hearing loss and recommend a solution such as a hearing aid.

From handheld tympanometers to desktop models that offer a complete range of middle ear tests, e3 Diagnostics has the tools you need. Our tympanometry devices will allow you to diagnose patients' hearing issues so they can improve their quality of life quickly. You can feel confident with our high-quality tympanometry equipment from respected manufacturers including MAICO, Interacoustics, Amplivox, and Grason-Stadler.

Amplivox 102 C

Amplivox Otowave 102C

Available different models (Otowave 102-C, 102-1 and 102-4) the Amplivox Otowave 102 is a handheld, portable tympanometer that provides fast and accurate middle-ear measurements with the utmost reliability. Its lightweight, ergonomic design makes it fit comfortably in your hand during testing, and allows you to conduct tests on the go.

Additionally, the Otowave 102 is easy to operate as it displays information on its high-resolution screen before, during, and after each test. After review, results can be saved within internal memory with a patient identifier, printed via infra-red connection to a printer, or transferred to a PC.

Features and Benefits:

  • Fast accurate middle ear measurements
  • Ergonomic shape
  • Totally portable
  • Intuitive use
  • Large graphics display
  • Programmable reflex test
  • Optional portable printer and PC interface
  • No external power or data cables


Brochure

Otowave 102 Supplies

Request a Quote

We understand that you have a choice when it comes to choosing your equipment and are dedicated to providing you with the highest quality instrumentation available.Contact us now for your free, no obligation quote and discover why we are the preferred Authorized Distributor and Service Provider to the world’s leading manufacturers.  (Completing our online form does not sign you up for electronic advertising.)

 

Specifications

Tympanometry Measurements

  • Probe tone: 226Hz +/-0.1%, 85dB +/-2dB
  • Pressure range: +200daPa to -400daPa +/-10daPa
  • Direction of sweep: Positive to negative
  • Volumetric range: 0.2 to 5ml +/- 0.01ml or 10% over range whichever is greater
  • Analysis performed: Compliance peak level, compliance peak pressure level, gradient and equivalent ear canal volume Re ex measurements

Reflex Measurements

  • Otowave 102-1: 1kHz +/-0.1%
  • Otowave 102-4: 500Hz, 1kHz, 2kHz & 4kHz +/-0.1%
  • Reflex dB range: 85 to 100 dBHL (programmable in 5 or 10 dB steps)
  • Reflex measurement range: 0.01ml to 0.5ml +/-0.01ml 
  • Analysis performed: Reflex maximum amplitude and pass/fail at each test level

Data management

  • Internal database: 30 patient records. Patient record identification. Data transfer to designated printer or PC application
  • Electronic data storage (database PC requirements): NOAH aud module. Amplivox impedance module. Infra-red PC port.
  • Printing: Designated printer: high speed portable thermal printer Data transfer: Infra-red IrDA 9600 Baud Printing may also be completed via a PC with the relevant applications

Physical Data

  • Power (battery): 4x Alkaline AA or 4x NiMH (>=2.3Ah) rechargeable
  • Dimensions (mm): 210 long x 80 wide x 40 high envelope
  • Weight: 380 grams (including batteries)

Standards

  • Safety: EN60601-1 EMC: EN 60601-1-2
  • Impedance: EN60645-5 Type 2 tympanometer
  • CE Mark: Complies to EU